Military Mobile Substation E-House

Skid-mounted mobile substation for defense infrastructure, emergency power, and field deployment programs — transformer, MV switchgear, and DC power integrated on one camouflage-finished transportable unit, ready to connect on arrival.

Mobile SubstationPackage SubstationRapid Project Deployment UnitTemporary Power Equipment EnclosureBackup Power Equipment Enclosure

Key Metrics

Skid-mounted
Structure
25 yr
Life
IP54·55
Rating
C3-C5
Corrosion

Product Features

Feature icon

One-skid station

Transformer, switchgear, and DC power on a single skid — transported, lifted, and positioned as one unit.

Feature icon

One-skid station

Transformer, switchgear, and DC power on a single skid — transported, lifted, and positioned as one unit.

Product Details

A steel skid base gives the whole station its installation foundation and transport capability: the transformer mounts on the external skid platform, HV bushings connect to the indoor switchgear through insulated cables, and the local terminal box and cable fixing are pre-fabricated with the skid. Lifting and towing provisions are built into the base, so transformer and enclosure travel, lift, and set down as one unit. Transformer rating and brand are confirmed to the project scope.

Skid Platform & Transformer Integration

The cabin provides centralized installation space for MV switchgear: cabinet foundations, busbar and cable routes, the operating aisle, and maintenance clearances are developed in-factory from the equipment list. Protection and metering panels are integrated on the cabinet fronts, and incoming/outgoing cables enter through pre-fabricated, sealed openings. Switchgear can be customer-supplied or sourced and integrated to the project scope, with voltage class configured to the target market.

Live equipment zones are separated behind perforated-mesh guard doors with viewing windows and warning marking, so operators complete inspection and status checks from the aisle side. Ventilation grilles maintain cabinet cooling, and anti-slip steel flooring and cable trays organize the internal routes. Guard layout is set before manufacture around the equipment arrangement and maintenance access.

The DC power system is integrated with the cabin: battery banks install in tiers in a dedicated battery cabinet, and the DC feed cabinet carries charging, distribution, and monitoring panels — continuous control power for protection, metering, and emergency lighting. Battery capacity, DC voltage, and feed circuits are configured per project, with cabinet ventilation and inspection access arranged in the factory.

Wall-mounted industrial air conditioning is sized to the equipment heat load and combined with ventilation and dehumidification to control cabin temperature and humidity and prevent condensation. Environmental design targets are configurable to the deployment environment — operating temperature typically −40 to +55 °C, altitude up to 4,000 m (derated), corrosion C3-C5 — keeping primary and secondary equipment stable through field and harsh-climate service.

Lighting, service sockets, HVAC supply, and monitoring circuits feed from a centralized auxiliary distribution panel with clearly labeled miniature-breaker circuits and tidy routing. Emergency lighting, communications interfaces, and operator panels are pre-fabricated with the cabin, supporting O&M work at night and under emergency conditions. Auxiliary distribution assemblies are designed and manufactured by ETENZ, with circuit configuration confirmed to the equipment list.

Delivery Scope Options

Scope 1

Enclosure Supply

For customers with their own equipment integration and site commissioning capability. ETENZ supplies the skid base and enclosure structure with equipment foundations, cable entries, earthing, and lifting/transport provisions.

Scope Includes:
Skid base, enclosure frame, panels, doors, insulation, and weatherproofing
Transformer platform and cabinet-row installation foundations
Earthing network and lightning protection interfaces
Dimensional, structural, and packaging inspection
Scope 1

Enclosure Supply

For customers with their own equipment integration and site commissioning capability. ETENZ supplies the skid base and enclosure structure with equipment foundations, cable entries, earthing, and lifting/transport provisions.

Scope Includes:
Skid base, enclosure frame, panels, doors, insulation, and weatherproofing
Transformer platform and cabinet-row installation foundations
Earthing network and lightning protection interfaces
Dimensional, structural, and packaging inspection

Technical Specifications

Product Type
Skid-mounted mobile substation
Structure
Integral skid unit
Main Equipment
Transformer / MV switchgear / DC power
Integrated to scope
Voltage Class
Global / regional levels
50/60 Hz
Dimensions
Custom to equipment and transport
mm
Design Life
25
years
Protection Rating
IP54 / IP55
Up to IP65
Anti-Corrosion
C3-C5 (ISO 12944)
Camouflage finish
Operating Temperature
Typ. −40 to +55 (configurable)
°C
Altitude
≤ 4,000 (derated)
m
HVAC Configuration
Air-con / dehumidification / ventilation
Heat-load based
Fire & Security
Detection & alarm interfaces / access & video
Pre-fabricated
Earthing & Lightning
Equipotential / earthing bar
Transport & Installation
Whole-skid transport / crane placement
Factory Testing
Pre-shipment inspection + energized function check
Witness optional
Warranty
12 (extendable to 24)
months
Standards Alignment
IEC / IEEE
Project-specific

Product FAQs

Power missions that need rapid deployment and whole-unit relocation: field exercises, remote outposts, emergency restoration and standby power, disaster response, and temporary construction supply. It also serves temporary substation needs on mining, oil & gas, and other remote industrial sites.

Defined by project scope: equipment can be customer-supplied, customer-specified, or sourced by ETENZ to the equipment list. ETENZ provides the installation foundations, cabin integration, inter-cabinet wiring, and interface pre-fabrication, with main-equipment ratings governed by the project technical agreement.

Yes. The finish is applied over the C3-C5 (ISO 12944) anti-corrosion coating system, with camouflage pattern and colors confirmed to the deployment environment and customer requirements. A standard industrial finish is also available.

Yes. Enclosure Supply, Interface Pre-Fabrication, and Systems Integration options are selected by equipment sourcing and site integration capability — Enclosure Supply already includes equipment foundations and lifting/transport provisions.

The station is a skid-mounted unit designed to road-transport constraints. On site it is crane-placed onto a hardstand or prepared foundation (foundation requirements confirmed per project), connected, checked, and put into service — and relocated whole when the mission ends.

Application and deployment environment (temperature, altitude, corrosion requirements), voltage class and capacity needs, main-equipment list or sourcing scope, transport constraints, finish and appearance requirements, and estimated delivery quantity.

Related Solutions

Power & Control

MV/LV Switchgear E-House Integration Solution

For industrial plants, utility infrastructure, data centers, and renewable-energy connection projects, ETENZ integrates MV/LV switchgear layouts, enclosure interfaces, ventilation or cooling, fire and grounding provisions, cable routes, and factory checks into a prefabricated E-House delivery scope, with enclosure supply, pre-installation, complete E-House delivery, and OEM/ODM cooperation options.

MV/LV Switchgear E-House Integration Solution
Synchronous Condenser Electrical E-House Integration Solution
High-Voltage VFD Prefabrication Solution
Data Center Power E-House Solution
Prefabricated E-House Project Delivery Solution