Control E-House

Control E-House

#EH-SE-001

Product Overview

When protection relays, control panels, communications cabinets, DC power, and station control systems need to be housed and delivered as an integrated unit, coordinating panel layout, cable routing, and interface boundaries on site consumes significant project time. ETENZ's Control E-House starts from the customer's panel list — equipment platforms, auxiliary power, HVAC, and communications interfaces factory-fabricated and inspected, ready for direct site connection on arrival.

Key Metrics

Prot / Ctrl
System
SCADA / BMS
Monitoring
AC / DC
Power
IEC / NEMA
Standards

Application Scenarios

Secondary Equipment E-HouseRenewable Grid-Connection Power DistributionBattery Energy Storage StationCompute Site Power Distribution UnitPLC/MCC Control RoomCampus Distribution RoomEdge Site Equipment EnclosureMobile Substation

Product Features

Feature icon

Enclosure Layout

Layout developed from the customer's panel list and station control diagram — aisle widths, door swing, spare positions, and cable tray paths confirmed, with front-access operation and rear-access maintenance coordinated before manufacture.

Feature icon

Auxiliary Power

Lighting, auxiliary power, earthing bars, lightning protection, terminal boxes, and inter-panel cable routes pre-fabricated at the factory. Site teams connect by interface list — no additional opening or re-wiring required.

Feature icon

HVAC & Dehumidification

Air conditioning, ventilation, dehumidification, and environmental monitoring configured to equipment heat load, site climate, altitude, and unattended operation requirements.

Feature icon

Security & Fire

Access control, video, smoke/temperature detection, fire suppression, and emergency lighting pre-fabricated with the enclosure — complete safety access conditions for unattended operation and remote management.

Feature icon

Monitoring & Communications

Cabinet positions, cable routes, and interface boundaries reserved for SCADA, EMS, BMS, and station control communications — pre-adapted to monitoring platforms and protocols, ready to connect on arrival.

Feature icon

Batch Delivery

Standard enclosure types, interface libraries, and process documents established for batch programs — brand appearance, nameplate packaging, and factory inspection coordinated to customer requirements.

Product Details

The Control E-House is built on a transportable, liftable, and maintainable steel structure providing centralized installation space for protection, control, communications, DC power, UPS, and station control equipment. Enclosure design is adapted around zoning, door configuration, cable entry openings, maintenance access, and equipment interface requirements — confirmed from the customer's equipment list before manufacture.

Enclosure Platform

Internal layout must coordinate panel dimensions, front-access operation, rear-access maintenance, terminal wiring, fiber routing, inter-panel cabling, spare positions, and expansion space. ETENZ develops installation foundations, aisle widths, door swing, equipment stops, and cable tray paths from the customer's panel list and station control diagram — the confirmed layout becomes the manufacturing basis.

Cable entry openings, trays, fiber routes, terminal boxes, earthing bars, lightning protection, inter-panel cabling, and field communications interfaces can be pre-fabricated to installation-ready condition. Interface design is coordinated with site wiring and communications architecture — reducing field modification work at site connection.

Secondary equipment is sensitive to temperature, humidity, condensation, dust, and power continuity. HVAC configuration follows equipment heat load, site climate, altitude, anti-corrosion grade, and unattended operation requirements. Air conditioning, ventilation, dehumidification, filtration, and environmental monitoring interfaces are coordinated with the enclosure design and confirmed before manufacture.

For protection relay manufacturers, automation equipment suppliers, system integrators, EPC teams, and international delivery programs, ETENZ supports structural detailed design, prototype verification, batch replication, brand appearance, nameplate packaging, pre-shipment inspection, and delivery documentation. Batch programs can standardize enclosure types, interface libraries, and inspection procedures to improve multi-site delivery consistency.

Delivery Scope Options

Scope 1

Enclosure Supply

For customers with their own secondary equipment integration and site commissioning capability. ETENZ supplies the enclosure structure with panel installation interfaces, cable entries, earthing, and transport provisions.

Scope Includes:
Enclosure frame, panels, doors, partitions, insulation, and weatherproofing
Panel installation bases, cable entries, lifting provisions, and site fixing interfaces
Earthing network and lightning protection interfaces
Dimensional, structural, and packaging inspection
Scope 2

Interface Pre-Fabrication

For protection relay manufacturers, equipment suppliers, and EPC teams seeking to reduce site cable routing, opening, and installation coordination. Builds on enclosure supply with pre-fabricated cable routes, fiber paths, earthing, auxiliary power, HVAC, fire suppression, and access control interfaces.

Scope Includes:
Cable entries, trays, fiber routes, terminal boxes, and earthing bars pre-fabricated
Auxiliary power, lighting, service sockets, and DC power interfaces
HVAC, ventilation, dehumidification, and environmental monitoring interfaces
Fire suppression, access control, video, and communications conduit provisions
Scope 3

Systems Integration

For OEM/ODM programs requiring higher factory completion. ETENZ coordinates auxiliary distribution, HVAC, fire suppression, environmental monitoring, access control, communications interfaces, and intelligent control to customer secondary equipment and project standards.

Scope Includes:
Auxiliary distribution, UPS interfaces, DC power, lighting, and service sockets assembled
HVAC, dehumidification, filtration, and environmental monitoring systems integrated
Fire suppression, access control, video, alarm, and communications systems pre-installed
Pre-shipment assembly, earthing, interface, labeling, and document inspection

Technical Specifications

System Type
Protection / Control / Communications
Project-specific
Control Power
AC / DC
Project-specific
Communications Interface
Fiber / Ethernet / Serial
Project-specific
Monitoring Interface
SCADA / EMS / BMS
Enclosure Dimensions
Custom
Transport constraints
Protection Rating
IP54 / NEMA 3
IP65 / NEMA 4 available
Anti-Corrosion Level
C4 / C5 (ISO 12944)
Project-specific
HVAC Type
HVAC / Dehumidification / Ventilation
Heat load based
Earthing & Lightning
Equipotential / Earthing Bar
Standards Compliance
IEC / NEMA / UL / CE
Project-specific

Product FAQs

Suited for substations, renewable grid connection, energy storage stations, data center power distribution, industrial facilities, campus distribution rooms, edge communication sites, and mobile substations — wherever protection, control, and communications equipment needs to be housed and delivered as a pre-fabricated, interface-ready unit.

Protection relays, control panels, communications cabinets, automation controllers, DC power panels, UPS, station control systems, SCADA/EMS/BMS interfaces, fiber distribution, environmental monitoring, fire suppression, access control, and video — configured to the customer's panel list and scope boundary.

Yes. ETENZ manufactures to customer brand, panel list, interface standards, enclosure dimensions, and batch delivery schedule. Long-term programs can standardize enclosure types, interface libraries, process documents, and inspection procedures.

Application type and site location, panel list and dimensions, station control system diagram, cable entry direction and quantities, communications and fiber interface requirements, HVAC requirements, protection rating, anti-corrosion level, transport constraints, and estimated delivery quantity.

Yes. Enclosure Supply, Interface Pre-Fabrication, and Systems Integration options are available based on customer equipment scope and site integration capability.

Enclosure structure, protection rating, anti-corrosion, electrical interfaces, communications, HVAC, safety, and documentation can be adapted to IEC, ANSI/IEEE, BS EN, and other project-specified standards. Certification and third-party inspection requirements are confirmed during technical review.

Related Solutions

Data Center and Compute Facility Solutions

Data Center Power E-House Solution

A factory-built power E-House solution for data center operators, OEMs and system integrators that need MV/LV power rooms with coordinated HVAC, monitoring, fire-safety, security and site handover interfaces.

Data Center Power E-House Solution
Synchronous Condenser Electrical E-House Integration Solution
High-Altitude Integrated E-House OEM Solution