The first three are the same equipment under different local names: MV switchgear, transformer and LV board in one outdoor unit. Compact substation is usual in Malaysia, India and Europe; package or packaged substation in the Gulf and the UK (Egypt uses both); mini substation in South Africa and Zambia. Australian networks also say kiosk or padmount substation. IEC 62271-202 (2022 edition) calls the class prefabricated substations. A unit substation is a different purchase, because the MV switchgear is not an integral part of it.

Compact Substations
For contractors and project owners: MV switchgear, transformer and LV board in one unit, ready to connect. The housing alone is also available.
Key Metrics
Product Features
Ready to connect
The station is assembled and wired before shipment, so your site crew only builds the foundation and makes the incoming and outgoing connections.
Ready to connect
The station is assembled and wired before shipment, so your site crew only builds the foundation and makes the incoming and outgoing connections.
Small footprint
A station with fully segregated compartments takes about 1/10 to 1/5 of the plot a conventional civil-built substation of the same capacity needs.
From 6 kV to 35 kV
Pick the type by voltage level, from a 6 or 10 kV distribution point to a 35 kV incomer, anywhere from 50 to 20000 kVA.
In line or clustered
A long narrow plot suits compartments in line up to 1250 kVA, and a squarer plot suits the clustered layout up to 400 kVA.
Ring main or radial
Connect it to a ring main, a dual supply or a radial feeder, add MV metering, and build the LV circuits to your load list.
Choice of enclosure
Pick the enclosure material and colour for the site: appearance for residential areas, corrosion resistance for coastal and chemical plants.
Product Details

A 6 or 10 kV distribution point goes with fully segregated compartments: in line up to 1250 kVA, or clustered up to 400 kVA on about 2.5 × 2.4 m. A 35 kV incomer needs the multi-box station, which steps down to 10, 6.3 or 0.4 kV at 400–20000 kVA. If the plot is tight and the job is 12/0.4 kV at 1000 kVA or less, the pad-mounted style stands on just 2000 × 1620 mm.

Each compartment has its own doors opening from outside. The MV compartment takes a ring main unit, or radial or dual-supply switchgear, rated 200–630 A, with MV metering if required and full mechanical interlocking. The transformer compartment holds a low-loss oil-immersed unit (noise below 55 dB) or a dry-type (below 65 dB), with automatic forced-air cooling and lighting, plus rails on request to roll the transformer out through the side doors. The low voltage compartment has the LV distribution board, panel or cabinet type, rated 100–3000 A, with circuits for power and lighting, reactive compensation, energy metering and measurement.
In line, the three compartments run end to end. At 200–630 kVA that makes 4140 × 2590 × 2320 mm, the size usually seen at mines, oilfields and construction sites; at 800–1250 kVA it makes 5184 × 2500 × 2626 mm, more common in residential areas. Clustered, either the transformer or the MV compartment takes one side and the remaining two share the rest, all in 2500 × 2400 × 2320 mm for 50–400 kVA, also common in residential areas.
One to three movable sealed boxes hold the primary and secondary equipment, typically a 35 kV switch box, a main transformer box and a 10 kV switch box with cable between them. Ratios are 35/10, 35/6.3 and 35/0.4 kV at 400–20000 kVA, with 35 kV breakers at 1250, 1600 or 2000 A and 10 kV breakers up to 3150 A. The 35 kV lines can come in and go out overhead or by cable. Oil transformers above 4000 kVA usually stand outdoors behind a safety guard. Shipment is in several transport units, with withdrawable breakers packed separately.
Transformer and MV switch sit in two separate oil tanks, so arcing from operating the load-break switch stays in the switch tank’s oil and does not affect the transformer oil. The MV side has a four-position 630 A and a two-position 100 A load-break switch with backup and plug-in fuses, and phase-loss protection can trip the incoming load-break switch and the LV breaker. Ratings are 12/0.4 kV, 100–1000 kVA in 11 steps, Dyn11, ONAN, ±2 × 2.5% off-circuit tapping, 50 dB noise and IP34. Footprint is always 2000 × 1620 mm; height and weight go with capacity, from 1600 mm and 1560 kg at 100 kVA to 2060 mm and 4650 kg at 1000 kVA. For a solar or wind plant, see the Pad-Mounted Transformer for Solar and Wind.
Choose from composite steel panels, stainless steel, aluminium alloy or cast fibre cement, all with corrosion treatment. Colour and appearance can follow the site; the photo shows a louvred front in dark blue and orange. Ventilation is both natural and forced: the transformer and LV compartments have air ducts, and exhaust fans start and stop at a set temperature. Coastal and chemical sites can have the coating upgraded, and where sand, dust or salt mist is a problem the protection can go up to IP54 per project.
Radial means a single incoming cable. A ring main has one cable in and one out, with a tee-off through a load-break switch and fuse to the transformer; tenders usually specify this as a ring main unit (RMU). Dual supply brings in two cables, again feeding the transformer through a load-break switch and fuse. Switch type, number of ways and metering position come from the project single-line; on the LV side you get incomer, feeders, reactive compensation and energy metering.
AC output from the inverters lands on the LV incoming panels, a double-split transformer with two LV windings steps it up, and an MV outgoing panel connects to the collector circuit. Each stage has its own compartment, in line or in an L, and the LV compartment can also hold a remote control device and an auxiliary transformer. Capacity, LV voltage and MV panels depend on the inverter and the collector scheme. Where you only need step-up and MV switching, a pad-mounted transformer takes less space.
For projects shipped overseas, the station can be built as a 20 ft high-cube container with a CSC plate, and the MV, transformer and LV rooms each open from outside. The photo shows one from ETENZ. If you only want the housing, go to the BESS Step-Up Substation Enclosure (20 ft).
Scope of Supply
Single Unit or Complete Package Supply
One or several stations to your order list, with MV panels, transformer, LV panels and enclosure assembled and wired before shipment. Oversize units are split to suit transport limits. If you only need the housing, or a walk-in unit, go to the E-House and enclosure products.
This covers:
Compact substation model comparison
Technical Specifications
| Parameter | Specification |
|---|---|
| Product form | Outdoor prefabricated substation: fully segregated compartments, multi-box or pad-mounted style |
| Models | YB□ / YBM / YBP-12/0.4, ZBW-40.5, ZGS11-12/0.4 |
| Altitude | ≤1000 m |
| Ambient temperature | Segregated compartments and multi-box: −25 to +40; pad-mounted style: −30 to +40 °C |
| Wind speed | Segregated compartments and pad-mounted style: ≤35; multi-box: ≤34 m/s |
| Transformer type | Segregated compartments: oil-immersed or dry-type; pad-mounted style: oil-immersed, ONAN; multi-box: per project |
| Pad-mounted style: height / weight by capacity | 100 kVA: 1600 / 1560; 125 kVA: 1600 / 1640; 160 kVA: 1600 / 1720; 200 kVA: 1700 / 1830; 250 kVA: 1700 / 2000; 315 kVA: 1780 / 2200; 400 kVA: 1780 / 2480; 500 kVA: 1780 / 2970; 630 kVA: 1980 / 3490; 800 kVA: 2060 / 3620; 1000 kVA: 2060 / 4650 mm / kg |
| Beyond these conditions | Agreed when ordering |
Product FAQs
Fully segregated compartments give MV, transformer and LV their own space in one enclosure, with room for switchgear, metering and protection. Pad-mounted style keeps the transformer and the MV switch in oil tanks for a smaller unit: two tanks with the oil kept apart on this page’s ZGS11, one shared tank on the Pad-Mounted Transformer for Solar and Wind. A multi-box station spreads the 35 kV switchgear, main transformer and 10 kV switchgear across up to three boxes joined by cable.
YB means a packaged station, followed by M for compartments in line or P for clustered; the box in YB□ stands for that letter. In ZBW, Z is combined, B is substation and W is outdoor. In ZGS11, ZGS means a packaged station and 11 is the design number. The figures that follow are voltages, so 12/0.4 means 12 kV on the MV side and 0.4 kV on the LV side.
Price follows the capacity, the transformer type and loss level, the number of MV and LV circuits, the enclosure material and protection, and transport. A budget price follows from the single-line and capacity.
In pad-mounted style, 630 kVA measures 2000 × 1620 × 1980 mm and weighs 3490 kg; 1000 kVA measures 2000 × 1620 × 2060 mm and weighs 4650 kg. With fully segregated compartments in line, 200–630 kVA measures 4140 × 2590 × 2320 mm and 800–1250 kVA measures 5184 × 2500 × 2626 mm, with the weight set by transformer type and configuration.
The project’s civil engineer designs it from the outline and base dimensions, weight, cable entry positions and, for oil-immersed units, oil containment requirements that ETENZ provides. For pad-mounted style the recommended plinth is level concrete, 2100 × 2500 mm, with the unit fixed by clamp plates and the cable trench and earthing below. Base references for fully segregated compartments: in line 3750 × 2290 mm at 200–630 kVA and 4880 × 2290 mm at 800–1250 kVA, clustered 2300 × 2200 mm.
Fully segregated stations come in composite steel panels, stainless steel, aluminium alloy or cast fibre cement; the 35 kV type uses glass-fibre cement board or aluminium composite panels with thermal lining. The standard rating is IP23D with fully segregated compartments and IP34 in pad-mounted style. For sand, dust or salt-mist sites it can go up to IP54 per project.
Yes. Panel builders can buy the housing alone and fit their own equipment. For a 20 ft container housing, see the BESS Step-Up Substation Enclosure (20 ft). If operators need to walk inside, that is a walk-in type: see the Containerized MV Switchgear E-House.
Those sit outside the standard series in the table, so 11/0.4, 22/0.4, 33/0.4 or 33/11 kV, 13.8 kV networks and 60 Hz are confirmed against your single-line and specification. The tests and documents needed are agreed at the same time.
The country and use; the station type; transformer type and capacity; the MV and LV single-line diagram or circuit list; any components with special requirements; enclosure colour; spare parts; altitude, temperature, sand and salt mist conditions; and site and transport limits. If the job has a BOQ, send that too.
Related Solutions
MV/LV Switchgear E-House Integration Solution
For industrial plants, utility infrastructure, data centers, and renewable-energy connection projects, ETENZ integrates MV/LV switchgear layouts, enclosure interfaces, ventilation or cooling, fire and grounding provisions, cable routes, and factory checks into a prefabricated E-House delivery scope, with enclosure supply, pre-installation, complete E-House delivery, and OEM/ODM cooperation options.
Related Products

Pad-Mounted Transformer for Solar and Wind

BESS Step-Up Substation Enclosure (20 ft)

Containerized MV Switchgear E-House

MV Switchgear E-House

Oil-Immersed Distribution Transformer

Cast Resin Dry-Type Transformer