ETENZ custom prefabricated equipment enclosure mobile hero, factory-built enclosure with integrated equipment
Prefabricated InfrastructureFeatured Solution

Custom Prefabricated Equipment Enclosures

Equipment-ready enclosures for equipment makers and integrators

Industrial Manufacturing & Process FacilitiesPower & Utility Grid InfrastructureEnergy Storage & Renewable InfrastructureCompute & Data Center InfrastructureWater Treatment & Environmental Facilities

ETENZ manufactures custom prefabricated equipment enclosures in Shanghai, China, built around your equipment: enclosure-only, or with power, HVAC, fire and monitoring fitted and factory-tested.

3,000+
Projects
20+
Countries
25 years
Design life

Ways to Work With ETENZ

Choose the model that fits your role; ETENZ starts work at the matching step.

Illustration of an ETENZ prefabricated equipment enclosure: switchgear, HVAC, fire suppression, CCTV and access control

With drawings Build-to-print equipment enclosures

Equipment makers and integrators with their own drawings have ETENZ build the enclosure, equipment bases and internal supports in series, to print.

  • Built and inspected to your specifications
  • Enclosure-only or with auxiliary systems fitted
  • Customers include NR Electric, Sungrow, Sieyuan Electric and Jereh

Equipment only Enclosures designed around your equipment

Share the dimensions, weight, heat load and interface positions of your equipment, and ETENZ designs the layout, equipment bases, ventilation and cooling, and penetrations.

  • Service access and lifting planned together
  • HVAC sized to the equipment heat load
  • Fabrication starts after drawing approval

Export projects Configured for the destination market

Destination standards, climate and transport limits are set at design stage; labels, nameplates and documents are produced in the language of the destination.

  • Products sold in more than 20 countries and regions
  • Delivered to projects in Germany and the United States
  • Shipping method stated before quotation

OEM / ODM Delivered under your brand

Colors, logo, nameplates, label language and documents follow your brand, for equipment makers selling packaged outdoor products.

  • Combines with build-to-print or design-around
  • One base design repeated across projects
  • OEM work since 2004

Delivery Scope

Three delivery tiers: Enclosure Only, Subsystem Integration or Factory-Integrated Module. Each tier can carry your brand.

Delivery Scope
Enclosure structure, coating and insulationIncludedIncludedIncluded
Doors, seals, earthing and bondingIncludedIncludedIncluded
Equipment bases, supports and lifting pointsIncludedIncludedIncluded
Cable, pipe and duct openings, sleeves and sealingIncludedProvided to drawingIncludedIncluded
LV auxiliary power, lighting and socketsNot includedIncludedIncluded
HVAC, ventilation and dehumidificationNot includedIncludedSized to the equipment heat loadIncluded
Fire detection, alarm and suppressionNot includedIncludedSupplied and installed by ETENZ or as you specifyIncluded
Access control, CCTV and environmental monitoringNot includedIncludedIncluded
Main equipment installedNot includedNot includedPer project; E-⁠Houses can be fitted at the factory
Factory inspectionIncludedStructure, dimensions and coatingIncludedAuxiliary systems tested item by itemIncludedComplete enclosure tested

IncludedNot includedCells with text: conditional or configured per project

Main equipment such as switchgear, batteries, gensets and chillers comes from you or the equipment supplier, who is responsible for its performance and commissioning.

Built around your equipment

Layout, bases, ventilation and penetrations follow the equipment that goes inside, whether you call it an enclosure, a custom equipment container or a non-standard container.

  • Row of protection and control panels inside a control E-House, over the raised-floor frame

    Switchgear, GIS and panels

    Operating and service aisles follow the panel line-up, cable entry, busbar and wall-bushing positions are provided to drawing, and HVAC with dehumidification keeps condensation out. Single, multi-module and two-storey E-⁠Houses delivered.

  • Battery racks inside a BESS enclosure, one pack pushed into place, with fire piping and detectors above

    Batteries and PCS

    Racks are designed to the pack dimensions and load per shelf; liquid cooling, fire protection and gas detection are fitted at the factory up to battery-ready. You or the system integrator install the packs.

  • High-density miner racking and cable management

    Compute equipment

    Enclosure and airflow are designed around the rack layout, air or liquid cooled, with power distribution and monitoring fitted at the factory. 200 units delivered OEM in one year for a North American operator.

  • Airflow diagram: intake at the alternator end, radiator discharge through a sealed duct

    Diesel gensets

    Intake and discharge openings are sized from the radiator area; exhaust and silencer supports, acoustic lining, fuel tank and drip tray are fitted, and the enclosure is delivered genset-ready. Noise is designed to your limit.

  • Chiller plant enclosure interior before decking: pumps on equipment bases across the open beam grid, chiller at left

    Chillers and pumps

    Layout and bases follow the chillers and pumps; refrigerant and water pipe openings, sleeves, sealing and supports are prepared for a chiller-ready enclosure. Piping installation and pressure testing stay with the plant integrator.

  • Cross-section diagram: intake air through a motorized louver, compressor heat out via inner and outer ducts

    Water treatment, fire systems

    RO skids and compressed air foam systems get a layout with piping provisions and service space; ducting, motorized louvers and floor insulation follow the system design.

From Inquiry to Delivery

Six steps from data review to shipment of the complete enclosure.

  1. Design sign-off
    Illustration of RFQ and data review
    01

    RFQ and data review

    Confirm the equipment list, site conditions, delivery tier and quantity.

  2. Design sign-off
    Illustration of the layout and interface freeze
    02

    Layout and interface freeze

    Confirm the general arrangement, equipment bases and penetration list.

  3. Sample validation
    Illustration of the first-article enclosure
    03

    First-article enclosure

    Build the first unit to the frozen design and verify assembly and interfaces.

  4. Sample validation
    Illustration of factory inspection
    04

    Factory inspection

    Before the first unit and every unit after it leave the factory, structure, dimensions and coating are inspected; fitted auxiliary systems are tested item by item, with records shipped with the enclosure.

  5. Series delivery
    Illustration of series production
    05

    Series production

    Every unit is built with the same process and to the same inspection standard.

  6. Series delivery
    Illustration of shipping and document handover
    06

    Shipping and document handover

    Each enclosure ships complete, with drawings, inspection records and O&M manuals handed over.

Prepare before you inquire

Equipment

Type, drawings, weight and mounting points

Operation

Heat release, airflow, noise and vibration

Site

Location, climate, altitude and corrosion class

Connections

Power, cable, pipe and duct entries

Delivery and scope

Tier, quantity and destination

Frequently Asked Questions

Can’t find your question? Include it in your inquiry.

ETENZ builds prefabricated enclosures around switchgear and GIS, synchronous condensers and STATCOMs, MV VFDs, batteries and PCS, compute equipment, diesel gensets, chillers, reverse osmosis systems and compressed air foam fire systems. For other equipment, send its dimensions, weight, heat load and interfaces for review.

ETENZ quotes per unit. The price depends on outline size, wall, roof and floor build-up and insulation, coating system and corrosion class, the number of doors and openings, the delivery tier (enclosure only, or with power, HVAC and fire systems fitted) and quantity. A per-unit quote follows once the equipment data is complete.

Yes. In the Subsystem Integration tier, ETENZ fits LV auxiliary power, lighting and sockets, HVAC and dehumidification, fire detection, alarm and suppression, access control and CCTV, and tests them before shipment. Suppression is supplied and installed by ETENZ or follows the system you specify.

Yes. Custom equipment containers, special-purpose containers and non-standard or custom-size containers are names for the same thing: a steel enclosure built around the equipment, on ISO ⁠20 ft or 40 ft dimensions or in non-standard sizes. ETENZ builds them for switchgear, batteries, gensets, chillers, water treatment and other equipment, enclosure-only or factory-fitted and tested.

Not always. Some enclosures are built to 20 ft or 40 ft ISO dimensions with corner castings so they ship as standard containers; others are purpose-built steel enclosures in non-standard lengths, extra widths or multi-module assemblies. Either way, ETENZ builds the enclosure new, with structure, openings and fit-out designed around the equipment.

Equipment: type, drawings, weight, mounting points and service clearances. Operation: heat release, airflow, noise and vibration. Site: location, climate, altitude and corrosion class. Connections: power, cable, pipe and duct entries. Delivery: tier, quantity and destination. From this, ETENZ sets the enclosure size and layout, equipment bases and lifting points, HVAC selection and penetrations, then quotes. Incomplete data is fine to start with.

Common outlines follow 20 ft and 40 ft containers; ETENZ also builds non-standard lengths, extra widths and multi-module assemblies such as an eight-module GIS E-⁠House and a 14-module two-storey E-⁠House. Enclosures with an ISO outline, corner castings and CSC approval ship as standard containers; over-width, over-height or non-standard units ship as special or out-of-gauge cargo, with the method stated before quotation.

The standard build uses a 2.0 mm galvanized roof, 1.6–⁠2.0 mm corrugated wall panels, 50 mm rock-wool insulation and a channel or square-tube steel frame, with a 25-year structural design life. Coating systems follow ISO ⁠12944 for C3 to C5; ingress protection is IP54 or IP55 as standard, with IP56 achievable.

Every unit is inspected for structure, dimensions and coating before it leaves the factory. Fitted auxiliary systems (power, lighting, HVAC, fire and monitoring) are tested item by item, and the records ship with the enclosure. Witness testing can be arranged for E-⁠Houses.

Yes. ETENZ builds to your drawings and acceptance criteria; colors, logo, nameplates, label language and documents follow your brand, and one design can be repeated across projects.

ETENZ operates a 70,000 m² manufacturing site in Fengxian, Shanghai, China, with more than 500 employees, and builds over 5,000 electrical equipment housings and prefabricated enclosures a year. The company holds ISO ⁠9001, ISO ⁠14001 and ISO ⁠45001 certifications and factory approval from the American Bureau of Shipping (ABS).

Lead time is quoted by quantity and delivery scope, and a first unit can be built for approval before series production. The enclosure warranty is 12 months, extendable to 24 months by project; warranty for the equipment inside comes from its supplier.

Have a project in mind?

Message us on WhatsApp or send an inquiry. We reply within 24 hours on working days.