Delivery spans enclosure-only supply, rack-ready cabin, factory-integrated module and OEM/ODM. You can buy the enclosure only (structure, power distribution and HVAC / fire / monitoring subsystem interfaces prepared); battery modules and the PCS are customer-furnished or supplied per project scope. ETENZ manufactures the enclosure and handles subsystem integration and does not warrant battery/PCS performance.




Battery Energy Storage Container (20 ft, 5 MWh)
For C&I and renewable storage developers, system integrators and equipment OEMs worldwide — 5 MWh of battery racks in one container; enclosure only to OEM/ODM.
The 20 ft 5 MWh Battery Energy Storage Container is ETENZ's containerized BESS for grid & C&I storage projects.
Rated at a nominal 5 MWh, it arranges multiple battery-rack rows inside a standard 20 ft ISO container and pre-integrates power distribution, HVAC, fire detection with pipe-network suppression, combustible-gas detection and monitoring as subsystem interfaces. ETENZ manufactures the enclosure and handles subsystem integration; battery modules and the PCS are supplied or pre-reserved per project scope. Delivery ranges from enclosure-only supply and rack-ready cabin to a factory-integrated module and OEM/ODM under your brand, suited to storage stations, C&I storage and renewable grid-connection sites.
Product Features
Containerized enclosure
Standard 20 ft container structure with multiple battery-rack rows; corner-casting lifting makes the whole cabin easy to ship and position, while forklift pockets serve the empty cabin.
Containerized enclosure
Standard 20 ft container structure with multiple battery-rack rows; corner-casting lifting makes the whole cabin easy to ship and position, while forklift pockets serve the empty cabin.
Multi-rack battery layout
Multiple battery-rack rows inside the cabin, with footprint and service aisles reserved per module type. Rated at a nominal 5 MWh, configurable to the battery selection.
Integrated subsystems
Power distribution, HVAC, fire protection, combustible-gas detection and monitoring interfaces are pre-built inside the cabin — wire the equipment on site and commission.
Pipe-network suppression
Smoke, heat and combustible-gas detection tie into the fire alarm control panel, with interfaces provided for pipe-network fire suppression and release.
Active thermal management
HVAC and forced ventilation are sized to the heat load to hold the working-temperature envelope for the batteries; cooling capacity is confirmed against the system heat load.
Product Details

Multiple battery-rack rows inside the cabin
Multiple battery-rack rows reserve footprint, service clearance and replacement aisles per module type, with cable routing and interfaces organized. Battery modules are supplied per project scope or customer-furnished; the nominal 5 MWh is configurable to the battery selection, and cell-level performance is defined by the equipment supplier.

Multiple battery-rack rows inside the cabin
Smoke and heat detection tie into the fire alarm control panel; suppression piping and release/interface points are laid out inside the cabin. The suppression system is configured per project and by the equipment party, while thermal-runaway protection and AHJ / fire-marshal review are led by the project owner.
The fire alarm control panel centralizes smoke, heat and gas detection plus audible-visual alarms, interlocking suppression release and emergency devices. Communication interfaces to upstream monitoring / fire host are prepared, with interlock logic confirmed per project.
Combustible-gas detectors monitor battery off-gassing risk inside the cabin, interlocking audible-visual alarms and gas warning signage. Ventilation and gas handling are configured to the battery supplier's and code requirements, with hazard assessment owned by the system party.
HVAC and forced ventilation organize airflow and heat exchange inside the cabin, holding the working-temperature envelope for the batteries against the heat load. Intake/exhaust, louvers and fans are sized to the heat load and system design, suited to outdoor and high-temperature sites.
Environmental monitoring for temperature/humidity and water ingress plus a control cabinet are integrated inside the cabin, with BMS alarm, EMS/SCADA and remote-monitoring communication interfaces prepared. Data and operation responsibility is defined by the system party; ETENZ supports the interfaces and documentation delivery.
Delivery Scope Options
Enclosure Only (Interface-Ready)
Scope 1The 20 ft containerised storage cabin is supplied enclosure-only, with every interface prepared: distribution and incoming connections, separated battery and electrical zones, and the openings and mounting positions for the climate, fire and monitoring subsystems. Battery racks can be pre-fitted. Battery modules and the PCS are free-issued by the customer or supplied separately — suited to projects that already hold the equipment or prefer to buy it themselves.
Scope Includes:
Technical Specifications
| Parameter | Specification |
|---|---|
| Nominal storage capacity | Nominal 5 MWh (configurable to battery module and layout) MWh |
| Structure type | 20 ft ISO containerized BESS cabin |
| Overall dimensions | 20 ft standard container baseline (approx. 6058×2438); height and layout per project mm |
| Roof / wall / frame | Roof 2.0 galvanized / wall 1.6-2.0 corrugated / 50 rock-wool insulation / channel-steel & square-tube frame mm |
| Ingress protection | IP54 / IP55 IEC 60529 |
| Corrosion grade | C3 / C4 / C5 (selected per environment) ISO 12944 |
| Ambient temperature | Working temperature range configured per layout (exact range confirmed per project) |
| Battery supply scope | Customer-furnished / supplied / reserved (batteries are supplier-provided by default) |
| Battery module / chemistry | Defined by the battery supplier (ETENZ does not warrant cell performance / safety) |
| Inverter / PCS scope | Included / housed / reserved / excluded; model and service clearance per project |
| Temperature control | HVAC / forced ventilation / combination (sized to heat load and system design) |
| Fire detection | Smoke / heat / gas detection + alarm + interlock interface NFPA 72 |
| Suppression / interface | Suppression piping / release / interface / FACP interface (suppression system is supplier-provided) |
| Monitoring / EMS interface | BMS alarm / EMS·SCADA integration / remote monitoring |
| Transport / lifting | Shipped as a whole; lifting points / corner castings, plus forklift pockets for the empty cabin (exact tonnage confirmed per project) |
| Warranty | Enclosure 12 (extendable to 24, project-dependent; battery/PCS warranty by the equipment supplier) months |
Product FAQs
5 MWh is a nominal capacity, configurable to the battery module type and layout. By default battery modules and the PCS are customer or integrated equipment, and ETENZ provides for the battery racks, cable routing and connection interfaces; they can be supplied and installed per scope if the project requires, but round-trip efficiency, cycle life and equipment certification are defined by the battery/PCS supplier.
The cabin integrates smoke, heat and combustible-gas detection tied into the fire alarm control panel for audible-visual alarms, with suppression piping and release/interface points laid out. The specific suppression medium and system configuration, thermal-runaway protection and local fire (AHJ) review are determined per project and by the equipment party; no UL 9540 / NFPA "pass" claim is made at the cabin level.
A combination of HVAC and forced ventilation is used, sized to the heat load to organize airflow and heat exchange inside the cabin. The actual cooling capacity is set by the system heat load, and the battery working-temperature range follows the battery supplier's limits; the design suits outdoor and high-temperature sites.
Yes. With standard cabin types and an interface library, ETENZ supports OEM/ODM and consistent multi-site delivery, customizable to the customer's brand, color, interface standards and non-standard sizes — well suited to volume, repeatable storage-station deployment.
The 20 ft ISO container is the baseline cabin type, customizable to equipment layout and shipping conditions; AC interfaces, voltage and the transformer/switchgear boundary are set per project; ingress rating IP54/55 and anti-corrosion C3-C5 are configured to indoor/outdoor use and environmental grade.
The enclosure is manufactured under the ISO 9001 / 14001 / 45001 systems; UL/IEC and UN 38.3 transport certificates for batteries and the PCS are provided by the equipment supplier and bound to the specific model, while declaration and carrier acceptance for battery transport rest with the shipping party.
We recommend providing: application scenario (storage station / C&I storage / renewable aggregation, etc.), battery module and PCS model, capacity and interfaces, system heat load, site climate and voltage level, transport and foundation conditions, and brand and delivery-documentation requirements. The more complete the information, the more precise the cabin and interface configuration.
Yes. To date, ETENZ products have been sold in more than 20 countries and regions across Asia, Europe, Africa, North America and South America, and delivered to over 3,000 projects.
Related Solutions
Custom Prefabricated Equipment Enclosures
Custom prefabricated equipment enclosure manufacturer in Shanghai, China, since 2002: enclosures for switchgear, batteries, gensets, chillers and water treatment, enclosure-only or factory-fitted and tested. OEM/ODM.
Related Products

All-in-One Energy Storage Cabin (10 ft)

Medium-Voltage Direct-Connect BESS Control Enclosure

BESS Step-Up Substation Enclosure (20 ft)

32-Pack BESS Enclosure (20 ft, 6.25 MWh)

Battery Energy Storage Enclosure (20 ft, 6.25 MWh)

Battery Energy Storage Enclosure (48 packs, 5 MWh)
Have a project in mind?
Message us on WhatsApp or send an inquiry. We reply within 24 hours on working days.