Modular AI Data Center Modules for Integrators and OEMs
Data Centers & Compute

Modular AI Data Center Modules for Integrators and OEMs

Factory-built modules for high-density AI racks, air- or liquid-cooled

ETENZ builds the container and fits power distribution, air or liquid cooling interfaces, fire safety and monitoring in the factory, so each module arrives ready to connect and repeat.

‎20/40 ft
ISO formats
25 years
Design life
5
Built-in systems

Solution Features

Factory-built units, shorter site work

Structure, rack support, power and cabling, airflow paths and service aisles are assembled and checked before shipment, so site work comes down to foundations, lifting, incoming power and connections.

Application Scenarios

New AI campus compute units

For AI campuses built in modules, the enclosure, power connection, airflow and liquid-cooling paths, fire safety, security and service aisles are delivered as one prefabricated unit.

Benefits

Standard modules organize compute capacity for phased build-out and later expansion
Structural, electrical and thermal integration moves into the factory, reducing site coordination
Common interfaces and documents give clear equipment boundaries and acceptance criteria
Compute module with both side doors open, showing the fan wall, filter wall and internal service aisle
A factory-built compute unit with airflow, filtration and service aisle formed before shipment

Detailed Solution

A modular AI data center module from ETENZ carries the enclosure structure, rack support and layout, low-voltage distribution, airflow management and liquid-cooling interfaces, network cabling, monitoring and alarms, fire safety, security and service aisles in one unit that can be shipped, installed and repeated. Compared with building on site, more of the design, assembly and inspection moves into the factory, and site work narrows to foundations, lifting, incoming power, cooling connections and commissioning. ETENZ supplies the enclosure and the integrated subsystems; servers, AI accelerators and network equipment are selected and supplied by the customer or a third party.

At system level a module typically includes the insulated enclosure, rack rows with hot and cold aisle containment, main distribution and branch circuits, PDUs with A/B feeds, earthing and bonding, lighting and service aisles, supply and exhaust air with filters, piping and CDU interfaces for cold-plate or rear-door liquid cooling, facility water interfaces for pressure, temperature, flow and leak detection, environmental sensors with access control and video, fire detection and release interfaces, and network switching with remote monitoring. Cooling can combine air cooling, DX, chilled water, free cooling and liquid-cooling interfaces to suit the heat load; cooling capacity, rack power density and rack count follow from the layout and the heat-load calculation.

Where AI capacity has to be replicated quickly, modules can be deployed singly, in pairs, in arrays or as clusters, with space reserved for incoming power, cooling, network, fire and service routes. Customers can start with one module or a small cluster to prove equipment and site conditions, then expand as power capacity, cooling, budget and equipment deliveries allow. Responsibility between the module, external chillers, site water and grid connection is agreed item by item in the interface matrix; site lifting and civil works are defined separately.