Read what the specification says. Where the technical specification names an ABB or Schneider platform, or the owner spare-parts regime is already tied to one component brand, an authorized platform is the answer; where the specification only sets voltage, current and short-circuit level, generic cubicle types usually give more selection room and shorter lead times. ETENZ builds both — send the single-line diagram and the specification wording and we will set the two options side by side.

Authorized-Platform Switchgear Assemblies
For project owners, panel builders and distribution contractors whose specification names an ABB or Schneider platform: ETENZ builds UniSafe-12, MDmax ST, BlokSeT and MDrail-E on their authorized platforms, supplied as standalone assemblies or installed as the primary equipment inside an MV switchgear E-House.
Key Metrics
Product Features
Licensed platforms
ETENZ builds UniSafe-12, MDmax ST, BlokSeT and MDrail-E on the ABB and Schneider authorized platforms, following the platform technical documents for cubicle structure, component fit and assembly practice rather than offering a lookalike substitute.
Licensed platforms
ETENZ builds UniSafe-12, MDmax ST, BlokSeT and MDrail-E on the ABB and Schneider authorized platforms, following the platform technical documents for cubicle structure, component fit and assembly practice rather than offering a lookalike substitute.
Licensed platforms
ETENZ builds UniSafe-12, MDmax ST, BlokSeT and MDrail-E on the ABB and Schneider authorized platforms, following the platform technical documents for cubicle structure, component fit and assembly practice rather than offering a lookalike substitute.
Fixed component set
Breakers, drawer units and main components on an authorized platform come from that platform own product range, so choosing the platform also chooses the component set — the point that separates these lines from open-selection cubicles, and one to settle at quotation.
MV and LV covered
UniSafe-12 covers 12 kV medium voltage, MDmax ST and BlokSeT cover 690 V low-voltage main distribution to 6300 A, and MDrail-E covers 250-630 A final power distribution, so the medium- and low-voltage line-ups of one project come from a single source.
Platform drawings
Primary connections, line-up arrangement, busbar sizing and cable entry direction follow the platform structural rules, and ETENZ fixes interface positions, inter-panel links and spare bay allocation on the project drawings before manufacture starts.
Secondary prewired
Protection relays, metering, CT/VT, auxiliary supplies and communication interfaces are mounted, wired and circuit-checked in the factory, with secondary signals brought to a terminal strip; supervisory control beyond that strip belongs to the customer side.
E-House ready
All four platforms can be delivered as the primary equipment inside an MV switchgear E-House or other power module, with line-up arrangement, busbar bridge and in-module interfaces detailed by ETENZ and the delivery boundary settled once at contract stage.
Product Details

UniSafe-12 MV switchgear
UniSafe-12 is 12 kV air-insulated metal-enclosed switchgear with a 42/75 kV rated insulation level, 630-2500 A on the main busbar, branch busbar and branch connectors, 31.5 kA short-time withstand current for 4 s, 80 kA peak withstand current, and a basic cubicle envelope of 2160 x 600(750/1000) x 1550 mm. Cubicle width is selected between 600, 750 and 1000 mm by functional unit, and ETENZ fixes the line-up composition and cable entry direction against the project single-line diagram.

UniSafe-12 MV switchgear
MDmax ST is rated 690/1000 V AC and 1500 V DC for insulation, 400/690 V AC and 750 V DC for operation, with a 6/8/12 kV rated impulse withstand voltage. The main busbar carries 6300 A with 100 kA short-time withstand for 1 s and 220 kA peak; the distribution busbar carries 2000 A, 80 kA and 176 kA; degree of protection is IP54. Functional units are available as withdrawable, removable and plug-in types, and the drawer construction takes up to 36 circuits in one cubicle.
BlokSeT is rated 380/690 V for operation, 660/1000 V for insulation and 50/60 Hz. The main busbar carries up to 6300 A with short-time withstand up to 100 kA for 1 s and peak withstand up to 220 kA; the distribution busbar reaches 2000 A, 80 kA and 176 kA; enclosure protection is IP30-IP54, with 20 mm clearance and creepage distance of at least 12.5 mm. Line-ups combine power distribution centre, motor control centre and reactive compensation sections.
The MDrail-E type designation reads in three parts: construction (S wall box, G floor cabinet), duty (L lighting, P power, A dual-source transfer, M motor starting and control, D digital, R precision row-head panel, H medical IT) and door type (01 metal, 02 glazed, 03 double-leaf). Wall boxes are rated 250/400 A with 10 kA/1 s short-time withstand, floor cabinets 630 A with 20 kA/1 s, protection reaches IP65, and the range is built to GB 7251.1, GB 7251.12 and the IEC 61439 series.
Delivery Scope Options
Standard configured assembly
Scope 1Standard configured assembly
Cubicles, main circuits, internal connections and basic secondary wiring are built against the platform structural rules and the confirmed primary scheme; labelling and standard delivery documents travel with the panels.
Scope Includes:
Standard configured assembly
Scope 1Standard configured assembly
Cubicles, main circuits, internal connections and basic secondary wiring are built against the platform structural rules and the confirmed primary scheme; labelling and standard delivery documents travel with the panels.
Scope Includes:
Authorized platform comparison
The four platforms span medium and low voltage, so each is listed against its own ratings with no cross-platform conversion. Cells marked as confirmed per project are issued once selection is agreed.
Technical Specifications
| Parameter | Specification |
|---|---|
| Product form | MV and LV switchgear assemblies built on ABB and Schneider authorized platforms |
| Authorized platforms | UniSafe-12 / MDmax ST / BlokSeT / MDrail-E |
| Rated operating voltage | 400 / 690 V AC low voltage; 12 kV medium voltage |
| Rated insulation voltage | 660 / 690 / 1000 V AC, by low-voltage platform |
| Main circuit rated current | 250-6300, by platform and busbar A |
| Short-time withstand current | 10-100 (1 s); UniSafe-12 is 31.5 (4 s) kA |
| Peak withstand current | 80-220, by platform and busbar kA |
| Degree of protection | IP30-IP54; MDrail-E up to IP65 |
| Enclosure form | Indoor assembled line-ups; MDrail-E also as a wall box |
Product FAQs
Not on an authorized platform — the component set is fixed by the authorization: UniSafe-12, MDmax ST and MDrail-E are built with ABB components and BlokSeT with Schneider components, which is precisely what choosing an authorized platform means. Where a project needs breakers and relays specified freely by brand, a generic cubicle type such as the KYN series is the route, and its component platform is agreed at technical-agreement stage.
Four things at minimum: the single-line diagram, system voltage and rated current, short-circuit capacity, and the clause in the project specification that names the platform or component brand — the last one decides which product line applies. For a contract-grade quotation, add the circuit schedule and busbar arrangement, protection and metering requirements, control supply and communication interfaces, installation environment, and the standards and document list for the destination market.
Both are 12 kV metal-enclosed switchgear. UniSafe-12 runs on the ABB authorized platform, with cubicle structure and component range set by the platform, 630-2500 A rated current and 31.5 kA short-time withstand for 4 s. The KYN series is a generic withdrawable metal-clad type covering up to 40.5 kV, configurable to 50 kA short-time withstand, from 550 mm cubicle width, with the component platform agreed per project. Specifications naming the ABB platform take the former; everything else converges on the latter by rating and bay dimensions.
Both reach 6300 A on the main busbar with 100 kA short-time withstand for 1 s and 220 kA peak; the difference is the licensor and the functional units. MDmax ST is the ABB platform, with withdrawable, removable and plug-in functional units and up to 36 circuits in one drawer cubicle at IP54. BlokSeT is the Schneider platform, with IP30-IP54 enclosure protection and line-ups combining power distribution centre, motor control centre and reactive compensation sections. Whichever the specification names is the one to take.
Current rating and installation position draw it. MDrail-E covers final power distribution and control boxes — 250/400 A wall boxes and 630 A floor cabinets installed on a floor, in a workshop or beside equipment. MDmax ST and BlokSeT are main distribution line-ups with busbars up to 6300 A installed in a low-voltage switchroom. Most projects carry both levels, and the split between switchroom outgoing feeders and floor-level boxes is fixed at drawing approval.
Yes. Switchgear is supplied as equipment while an MV switchgear E-House or other power module is supplied as an enclosure — the first is the panel itself, the second covers the enclosure, equipment layout, auxiliary systems and interface integration. Authorized-platform line-ups install inside a module just as well, with line-up arrangement, busbar bridge and in-module interfaces detailed by ETENZ, and the delivery boundary settled once at contract stage.
Standard documents travelling with the panels are the approved project drawings, component list, wiring records and packing list. Inspection records are issued to the scope agreed in the order technical agreement; where witnessed tests or a specific report format are needed, raise it during quotation and technical clarification so test and witness slots can be arranged. Platform authorization documents are provided at technical clarification stage as the project requires.
Related Solutions
Prefabricated E-House Project Delivery Solution
ETENZ delivers configurable prefabricated E-House projects for electrical equipment integration, covering enclosure manufacturing, layout, wiring paths, factory checks, interface coordination, and OEM/ODM cooperation.





Related Products

Containerized MV Switchgear E-House

MV Switchgear E-House

Integrated E-House

Withdrawable Low-Voltage Switchgear

Withdrawable Metal-Clad MV Switchgear - KYN Series