GKG-10(6) general mining-duty high-voltage switchgear cubicle

Mining Switchgear and Distribution Equipment

For mine and underground-works power designers, main contractors and assembly buyers: ETENZ supplies the three stages of a mine supply chain with the GKG-10(6) high-voltage cubicle, the GKD low-voltage cubicle and the PKD distribution box, as single panels or complete line-ups, and as the equipment inside a prefabricated substation module for a mine site.

Switchgear Room & Distribution RoomPrimary Equipment E-HouseTerminal Power Distribution UnitTemporary Power Equipment Enclosure

Key Metrics

0.38-10kV
Voltage
16-3200A
Current
31.5kA
Breaking
IP54-IP56
Protection

Product Features

Feature icon

One mine chain

Incoming and outgoing duty, power and lighting distribution, and chamber terminal distribution each have their own cubicle type: GKG-10(6) takes 10 kV and 6 kV supply and large HV motor starting, GKD carries 660 V and 380 V power and lighting, and PKD reaches the chamber operating rooms at 1140 V and below.

Feature icon

One mine chain

Incoming and outgoing duty, power and lighting distribution, and chamber terminal distribution each have their own cubicle type: GKG-10(6) takes 10 kV and 6 kV supply and large HV motor starting, GKD carries 660 V and 380 V power and lighting, and PKD reaches the chamber operating rooms at 1140 V and below.

Product Details

The five positions of GKG-□/□ are switchgear cubicle, mining duty, AC high voltage, rated current and rated voltage; the two figures either side of the slash are what an order has to state. GKD and PKD share the structure, with the third position becoming AC low voltage and the first becoming distribution box. An enquiry that says only "mining switchgear" without those two figures usually has buyer and supplier discussing different equipment.

GKG-10(6) model code broken down position by position

Cubicles are linked by a busbar bridge across the tops, and primary cables run bottom-in and bottom-out through the cable trench. Entries are sealed with explosion-proof compound after installation and unused openings are plugged with it as well — underground dust and dripping water entering through any one opening leave the creepage distance inside the cubicle no longer the figure on the drawing.

Short circuit and overload, zero-sequence overcurrent and overvoltage, earth leakage and undervoltage release, fault memory and self-test are all wired to the terminal strip in the works. Beyond the strip lie the mine monitoring system and the surface control room, with the interface form and signal list settled during the technical agreement.

Supply Scope and Delivery Boundary

All three apply to every order: what is supplied, how far secondary work goes at the works, and which inspection records and documents ship with the cubicles.

Single Cubicle or Complete Lineup Supply

Cubicles are supplied singly or as a complete lineup against the order schedule. Enclosure, main circuit and internal connections are assembled at the works and shipped as complete cubicles; where transport limits apply, the lineup is split and the joining interface is set beforehand. Where the cubicles are to arrive inside a prefabricated cabin, the E-House line takes on the enclosure, internal arrangement and cubicle fixing, and the switchgear is delivered as equipment housed within it.

This covers:
Single cubicle or complete lineup
Complete-cubicle shipment and split points
Joining and fixing interface
In-cabin delivery handled by the E-House line

Single Cubicle or Complete Lineup Supply

Cubicles are supplied singly or as a complete lineup against the order schedule. Enclosure, main circuit and internal connections are assembled at the works and shipped as complete cubicles; where transport limits apply, the lineup is split and the joining interface is set beforehand. Where the cubicles are to arrive inside a prefabricated cabin, the E-House line takes on the enclosure, internal arrangement and cubicle fixing, and the switchgear is delivered as equipment housed within it.

This covers:
Single cubicle or complete lineup
Complete-cubicle shipment and split points
Joining and fixing interface
In-cabin delivery handled by the E-House line

Mining switchgear and distribution equipment selection

The three types sit at three stages of a mine supply chain and their ratings are not on the same scale, so each is listed against its own figures with no conversion across types. Cells marked as project-confirmed are given once the system conditions are settled.

Position in the supply chain
Incoming, outgoing and HV motor starting
Rated voltage
10, 6 kV
Rated current
50, 100, 150, 200, 315, 400, 500, 630, 800, 1000, 1250
A
Enclosure construction
Metal-enclosed withdrawable, breaker truck
Main protection functions
Short circuit, overload, zero-sequence OC and OV, over/under-voltage
Short-circuit breaking and withstand
31.5 kA breaking, 80 kA peak, 4 s
Degree of protection
IP54
IP code
Suitable locations
Mining, metro, wind, residential and industrial consumer substations
Altitude and ambient temperature
1000 m, −20 to +40 °C

Technical Specifications

Product form
General mining-duty HV and LV switchgear cubicles and distribution box
Models
GKG-10(6) / GKD / PKD
Rated voltage
10, 6 kV (high voltage); 1140, 660, 380 V (low voltage)
Rated current
16–3200, by cubicle type
A
Rated short-circuit breaking current
31.5 r.m.s., GKG-10(6)
kA
Rated peak withstand current
80 peak, GKG-10(6)
kA
Rated short-circuit duration
4, GKG-10(6)
s
Degree of protection
IP54 (cubicles); IP21 and above, up to IP56 (box)
Operating altitude
1000 (cubicles); 3500 (box)
m
Ambient temperature
−20 to +40 (cubicles); −5 to +40 (box)
°C

Product FAQs

By where they sit in the supply chain. High-voltage incoming and outgoing duty at an underground or surface substation, and large HV motor starting, use GKG-10(6) at 10 kV and 6 kV; power and lighting distribution downstream of the transformer low-voltage side uses GKD at 660 V and 380 V to 3200 A; terminal distribution in a chamber operating room uses PKD at 1140 V, 660 V and 380 V, 16 A to 630 A. A mine site commonly has all three stages.

GKD suits mine sites, locations free of firedamp and coal-dust explosion hazard, and comparable underground industrial workings of non-coal mines; PKD suits non-coal mines and other underground locations, and requires the chamber operating room to be free of dripping water and dust ingress. GKG-10(6) is also used beyond mining, in metro, wind, residential and industrial consumer substations. A working face with firedamp or coal-dust explosion hazard needs flameproof mining equipment, which is outside the scope of this page.

A mine supply system runs with an unearthed neutral. On a single phase-to-earth fault the line voltages are unchanged and the fault current is small, so overcurrent protection cannot see it and the fault has to be found from zero-sequence current and voltage; on the low-voltage side earth-leakage protection watches insulation to earth directly. That is why GKG-10(6) carries zero-sequence overcurrent and overvoltage, and GKD carries earth-leakage protection and undervoltage release.

For GKG-10(6) the rated short-circuit breaking current and the rated short-time withstand current are both 31.5 kA r.m.s., the rated short-circuit making current and the rated peak withstand current are both 80 kA peak, the rated short-circuit duration is 4 s and the rated number of short-circuit breaking operations is 30; the breaking and making operating sequence is O-0.3s-CO-180s-CO five times, O fourteen times and CO eleven times. Short-circuit figures for GKD and PKD follow the project system conditions.

GKG-10(6) and GKD are both IP54. The GKD enclosure is 2 mm cold-rolled steel plate in RAL 7035, fixed pattern, with cable entry from the trench. PKD is an indoor enclosed pattern with a frame of cold-rolled or stainless steel, bent and welded and treated against corrosion, IP21 and above and up to IP56, maintained from the front, with a warning on the front door panel against opening the cover while live.

GKG-10(6) is built to GB/T 12173 for general mining-duty electrical equipment and to GB 3906 among others; PKD follows GB/T 12173, GB 7251.1, GB 14048.1, GB 14048.2 and Q/FJ009. Where the destination market requires supply against the corresponding IEC standards, raise it during technical clarification so the applicable standards and document list can be stated in the quotation.

Yes. Switchgear is supplied as equipment, while the enclosure, panel arrangement, auxiliary systems and interface integration a mine substation needs are supplied by the prefabricated power module line, with the panels delivered as equipment inside the module. The boundary between underground roadway and surface substation, together with transport dimensions and lifting conditions, is settled during the scheme stage.

Four things at minimum: the class of mine and the installation position — surface substation, underground substation or chamber; the system voltage and neutral earthing arrangement; the rated current and circuit schedule for each stage; and the short-circuit capacity. To quote to contract level, add the protection configuration and communication interfaces, cable entry and exit directions, the altitude and temperature of the installation environment, and the destination market standards and document list.

Related Solutions

Prefabricated Infrastructure

Prefabricated E-House Project Delivery Solution

ETENZ delivers configurable prefabricated E-House projects for electrical equipment integration, covering enclosure manufacturing, layout, wiring paths, factory checks, interface coordination, and OEM/ODM cooperation.