By where they sit on the low-voltage chain. The main distribution line-up on the transformer low-voltage side uses GGD at a 630–4000 A horizontal busbar; workshop or floor power distribution uses XL-21 at 630–1000 A busbar; sub-distribution and motor control use MNS-E at 63–630 A busbar, as either a wall box or a floor-standing box; terminal circuits use PZ30 at 6–100 A across 6 to 48 ways. Separate metering uses PML. Outdoor positions take JXF or XLW instead.

Distribution Boards and Terminal Distribution Boxes
For building and industrial electrical designers, M&E contractors and assembly buyers: ETENZ supplies the low-voltage distribution chain by level with GGD main distribution cubicles, XL-21 power distribution boxes, MNS-E sub-distribution boards, PML metering cubicles, PZ30 terminal consumer units and JXF/XLW outdoor enclosures, as single panels or complete line-ups and as equipment inside a prefabricated primary-equipment module.
Key Metrics
Product Features
Main to final board
From GGD with a 630–4000 A horizontal busbar, through XL-21 at 630–1000 A and MNS-E at 63–630 A, down to PZ30 terminal circuits at 6–100 A: four levels of the same low-voltage chain in one place, with busbar current and short-circuit withstand converging stage by stage.
Main to final board
From GGD with a 630–4000 A horizontal busbar, through XL-21 at 630–1000 A and MNS-E at 63–630 A, down to PZ30 terminal circuits at 6–100 A: four levels of the same low-voltage chain in one place, with busbar current and short-circuit withstand converging stage by stage.
Main to final board
From GGD with a 630–4000 A horizontal busbar, through XL-21 at 630–1000 A and MNS-E at 63–630 A, down to PZ30 terminal circuits at 6–100 A: four levels of the same low-voltage chain in one place, with busbar current and short-circuit withstand converging stage by stage.
Sealable metering
The PML metering chamber is separated from the outgoing breakers by a panel, the front door takes a dedicated sealable metering lock, and doors carrying meters are glazed so they can be read without opening; the current transformers sit on a swing-out door that carries a sealable lock of its own.
Fixed-mounted wiring
GGD and XL-21 are fixed-mounted and fixed-wired types with the breakers installed directly in the cubicle, without drawer units or plug-in contacts. Once the number of circuits is set the internal arrangement follows, and maintenance is carried out circuit by circuit with the board isolated.
Modular, extendable
MNS-E is built to a modular structure and can be extended with new distribution functions on request; standard components and accessible mounting keep replacement work short, and one system covers the range of low-voltage distribution boards and boxes at 630 A and below.
Outdoor to IP65
JXF reaches IP65 with a PU foam gasket, for harsher settings such as paper mills, sewage treatment plants and photovoltaic generation; XLW reaches IP54 with an added gasket strip, operated from an inner door behind an outer door with a toughened-glass viewing window, for sites, street lighting and outdoor lighting.
Product Details

The first three positions of GGD-0.4□/□ are LV distribution cubicle, fixed-mounted and fixed-wired, and the cabinet design code; 0.4 is the rated voltage, either side of the slash sit the breaker class and the rated current, and one further position carries the rated short-circuit breaking current. XL-21 shares the structure with the first two positions becoming power distribution box and company code. Writing those positions out on the enquiry settles which breakers the board carries and how much current it takes, without a second round of questions.

The horizontal busbar feeds the vertical distribution busbar through the incoming breaker and the measuring transformers, and feeder breakers then split it to the final circuits. Where a board sits on that chain sets its busbar current: 630–4000 A for a main distribution line-up, 630–1000 A for a power distribution box, 63–630 A for a sub-distribution board, and 6–100 A for a terminal consumer unit.
The energy metering circuit, current transformer secondaries, switch position and fault signals, and residual current monitoring are all wired to the terminal strip in the works. Beyond the strip lie building distribution monitoring and utility meter reading, with the interface form and signal list settled during the technical agreement; metering circuits that have to be sealed are prepared to the utility sealing requirement.
The box is machined on CNC machine tools, and the box mouth carries multi-layer machined protective channels that both stiffen it and keep dirt and water out when the door is opened; cable entries take sealing glands and the lock is a double-tooth barrel type. Material is chosen between cold-rolled steel and stainless steel according to how corrosive the environment is, and the IP65 and IP54 grades correspond to the two ways of making the gasket.
Supply Scope and Delivery Boundary
All three apply to every order: what is supplied, how far secondary work goes at the works, and which inspection records and documents ship with the cubicles.
Single Cubicle or Complete Lineup Supply
Cubicles are supplied singly or as a complete lineup against the order schedule. Enclosure, main circuit and internal connections are assembled at the works and shipped as complete cubicles; where transport limits apply, the lineup is split and the joining interface is set beforehand. Where the cubicles are to arrive inside a prefabricated cabin, the E-House line takes on the enclosure, internal arrangement and cubicle fixing, and the switchgear is delivered as equipment housed within it.
This covers:
Single Cubicle or Complete Lineup Supply
Cubicles are supplied singly or as a complete lineup against the order schedule. Enclosure, main circuit and internal connections are assembled at the works and shipped as complete cubicles; where transport limits apply, the lineup is split and the joining interface is set beforehand. Where the cubicles are to arrive inside a prefabricated cabin, the E-House line takes on the enclosure, internal arrangement and cubicle fixing, and the switchgear is delivered as equipment housed within it.
This covers:
Distribution board and terminal box selection
The seven types sit at different stages of the low-voltage chain and their busbar currents span three orders of magnitude, so each is listed against its own figures with no conversion across types. Outdoor enclosures are fitted with protective devices to order, and their ratings follow the devices fitted.
Technical Specifications
| Parameter | Specification |
|---|---|
| Product form | LV distribution line-ups, power distribution boxes and terminal consumer units |
| Models | GGD / MNS-E / XL-21 / PML / PZ30 / JXF IP65 / XLW IP54 |
| Standards | GB 7251.1, GB 7251.3; IEC 60439-1, IEC 60439-3 |
| Rated insulation voltage Ui | AC660 (line-ups); 400 (terminal box) V |
| Rated working voltage Ue | AC380; terminal box AC380/AC220 V |
| Rated frequency | 50 Hz |
| Busbar rated current | 6–4000, by board type A |
| Busbar short-time withstand current | ≤30 (line-ups); ≤6 (terminal box) kA |
| Busbar peak withstand current | ≤63 (line-ups); ≤9.18 (terminal box) kA |
| Degree of protection | IP20–IP54 (indoor); IP65/IP54 (outdoor enclosures) |
| Pollution degree | 3 |
| Operating altitude | ≤2000 (indoor) m |
Product FAQs
No. Withdrawable low-voltage switchgear runs a 6300 A horizontal busbar in a 2200 mm cubicle and its functional units are interchangeable drawers; MNS-E is a distribution board or box with a 63–630 A busbar, built as a wall box or a floor-standing box, in distribution, motor control and dual-supply duties. The two are an order of magnitude apart: main distribution line-ups take the former, sub-distribution and terminal control the latter.
No, and the difference matters. GGD, XL-21 and MNS-E work to GB 7251.1 and IEC 60439-1 at overvoltage category IV; the PZ30 product overview cites GB 7251 part three and IEC 60439-3 at overvoltage category III. Part three covers boards intended to be operated by ordinary persons — which is exactly the level a terminal consumer unit occupies in housing, offices and commercial premises, switched by people who are not electrically skilled.
PML at IP20 and PZ30 at IP30 belong only in a dry, clean indoor distribution room; GGD is IP30 as standard and IP40 on special request; XL-21 offers IP30, IP40, IP43 and IP54; MNS-E leaves the works at IP30 as standard and can be selected between IP20 and IP65 to suit the environment. Outdoor positions go straight to JXF at IP65 or XLW at IP54, both of which can take a stainless steel enclosure for corrosive settings.
PML comes in cubicle widths of 500, 600, 800 and 1000 mm at a depth of 600 mm. MNS-E wall boxes run 400–900 mm wide, 550–1000 mm high and 175–300 mm deep; floor boxes run 400/600/1000 mm wide, 1600/1800/2000 mm high and 350/400/450/500 mm deep. Dimensions for GGD, XL-21, PZ30 and the outdoor enclosures follow the number of circuits and the cable entry arrangement, settled at drawing approval.
This family is designed for indoor use: altitude not above 2000 m; ambient air not above +40 °C and not below −5 °C, with the 24 h mean not above +35 °C; relative humidity not above 50 % at a maximum temperature of +40 °C, higher humidity being permitted at lower temperatures, for example 90 % at +20 °C; inclination to the vertical not more than 5°; and a site free of fire and explosion hazard, of conductive or insulation-damaging dust, of chemical corrosion and of severe vibration. Transport and storage run −25 °C to +35 °C, and not above +70 °C for short periods of up to 24 h. Outdoor positions use JXF or XLW instead.
Yes. The boards are supplied as equipment, while the enclosure, panel arrangement, auxiliary systems and interface integration are supplied by the prefabricated power module line, with the boards delivered as equipment inside the module. Where medium and low voltage share one module it is handled as a primary-equipment module, with line-up sections, busbar bridges and in-module interfaces detailed together and the delivery boundary settled once at contract stage.
Four things at minimum: the low-voltage single-line diagram or circuit schedule; the incoming capacity and transformer parameters; the rated current and short-circuit level at each level; and whether the installation is an indoor distribution room or an outdoor position. To quote to contract level, add the metering and protection configuration, the required degree of protection, cable entry directions and cable sizes, the control supply and communication interfaces, and the destination market standards and document list.
Related Solutions
Prefabricated E-House Project Delivery Solution
ETENZ delivers configurable prefabricated E-House projects for electrical equipment integration, covering enclosure manufacturing, layout, wiring paths, factory checks, interface coordination, and OEM/ODM cooperation.